3 Core & Earth 6243Y

3 Core & Earth 6243Y

Domestic wiring cable. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.

Certification: BASEC Approved, ISO 9001. Standard: BS 6004

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6243Y1.01101318.1GreyBr/Bl/Gry7.5, 10, 16.5, 50, 100 2-way lighting circuits
6243Y1.51.511.31612.1GreyBr/Bl/Gry50, 100 Higher load 2-way lighting circuits
3 Core & Earth LSZH 6243B

3 Core & Earth LSZH 6243B

Low smoke zero halogen domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.

Certification: BASEC Approved, ISO 9001. Standard: BS 7211

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6243B1.01101718.1WhiteBr/Bl/Gry502-way lighting circuits
6243B1.51.511.32312.1WhiteBr/Bl/Gry50,100Higher load 2-way lighting circuits
6243B2.52.513.5547.41WhiteBr/Bl/Gry100
Single Core 6491X

Single Core 6491X

6491X Cable H07V-R/H07V-U to BS6004 is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances and apparatus.

Certification: BASEC Approved, ISO 9001. Standard: BS 6004

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6491X1.51.52.752412.1Blue, Black, Brown, Grey, G/YN/A100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
6491X2.52.53.61327.41Blue, Black, Brown, Grey, G/YN/A100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
6491X4.044.15424.61Blue, Black, Brown, Grey, G/YN/A50,100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
6491X6.064.75543.08Blue, Brown, G/YN/A50,100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
6491X10.0105.9731.83Blue, Brown, G/YN/A5, 10, 50, 100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
6491X16.0166.8981.15G/YN/A25, 50, 100In or on light fittings and inside appliances, switchgear and control gear. Green/Yellow for use as Earth Bonding.
Single Core & Earth 6241Y

Single Core & Earth 6241Y

Domestic wiring cable. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.

Certification: BASEC Approved, ISO 9001. Standard: BS 6004

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6241Y1.015.31318.1GreyBr/Bl100For general purpose wiring when an earth continuity conductor is required.
6241Y1.51.55.71612.1GreyBr/Bl100For general purpose wiring when an earth continuity conductor is required.
3 Core Steel Wire Armoured 6943X

3 Core Steel Wire Armoured 6943X

SWA Cable - power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.

Certification: BASEC Approved, ISO 9001. Standard: BS 5467

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6943X1.51.53012.1BlackBr/Bk/Gry10, 25Outdoor lights
6943X2.52.5407.41BlackBr/Bk/Gry10, 25Outdoor power
Double Insulated 6181Y

Double Insulated 6181Y

Doubled insulation cable for fixed installation in dry or damp areas for domestic and light industrial wiring: class 2 stranded copper conductor to BS EN 60228:2005.

Certification: BASEC Approved, ISO 9001. Standard: BS 6004

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6181Y16.0168.8761.21Grey, Blue,BrownBr/Bl, Br/Br, Bl/Bl50,100Consumer units
6181Y25.02510.51010.78Grey, Blue,BrownBr/Bl, Br/Br, Bl/Bl50,100Consumer units
Single Core LSZH 6491B

Single Core LSZH 6491B

Low smoke zero halogen cable suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.

Certification: BASEC Approved, ISO 9001. Standard: BS EN 50525-3-41

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6491B1.51.52.753112.1Blue, Black, Brown, Grey, G/YN/A5, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
6491B2.52.53.61437.41Blue, Black, Brown, Grey, G/YN/A5, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
6491B4.044.15564.61Blue, Black, Brown, Grey, G/YN/A5, 10, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
6491B6.064.75713.08Blue, Black, Brown, Grey, G/YN/A10, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
6491B10.0105.9971.83Blue, Black, Brown, Grey, G/YN/A10, 25, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
6491B16.0166.81301.15Blue, Black, Brown, Grey, G/YN/A3, 100In or on light fittings and inside appliances, switchgear and control gear particularly for situations in which low emissions of smoke and acid case is required in case of burning. Green/Yellow for use as Earth Bonding.
Twin & Earth 6242Y

Twin & Earth 6242Y

Domestic wiring cable. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.

Certification: BASEC Approved, ISO 9001. Standard: BS 6004

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6242Y1.017.61318.1GreyBr/Bl, Br/Br5, 7.5, 10, 16.5, 25, 50, 100Lighting circuits
6242Y1.51.58.51612.1GreyBr/Bl, Br/Br5, 7.5, 10, 16.5, 25, 50, 100Heavy duty lighting circuits
6242Y2.52.510.1217.41GreyBr/Bl5, 7.5, 10, 16.5, 25, 50, 100Ring mains and socket outlets
6242Y4.0411.6454.61GreyBr/Bl50, 100Higher load ring mains and socket outlets
6242Y6.0613.4573.08GreyBr/Bl5, 10, 16.5, 25, 50, 100Light duty cookers and showers
6242Y10.01016.6521.83GreyBr/Bl5, 10, 16.5, 50, 100, 500Higher load cookers and showers
6242Y16.01619691.15GreyBr/Bl50, 100, 500Light commercial and consumer units
Twin & Earth LSZH 6242B

Twin & Earth LSZH 6242B

Low smoke zero halogen domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.

Certification: BASEC Approved, ISO 9001. Standard: BS 7211

Product code Core
mm
Diameter
mm
Current
Amps
Resistance
Ohm/km
Outer sheath
colour
Inner core
colour
Length Usage
6242B1.017.61718.1WhiteBr/Bl100Lighting circuits
6242B1.51.58.52312.1WhiteBr/Bl100Heavy duty lighting circuits
6242B2.52.510.1427.41WhiteBr/Bl100Ring mains and socket outlets
6242B4.0411.6304.61WhiteBr/Bl100Higher load ring mains and socket outlets
6242B6.0613.4543.08WhiteBr/Bl100Light duty cookers and showers
6242B10.01016.6521.83WhiteBr/Bl100Heavy duty cookers and showers
6242B16.01619691.15WhiteBr/Bl50, 100Light commercial and consumer units